Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 577
Filter
1.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527808

ABSTRACT

ABSTRACT Purpose: To determine normal corneal tomographic parameters in children and adolescents without corneal disease or atopy diagnosis. Methods: This descriptive cross-sectional study evaluated patients aged 8-16 years who underwent a complete slit-lamp biomicroscopic examination and tomographic corneal evaluation by a dual Scheimpflug analyzer, excluding those with ocular disease (including allergic conjunctivitis) or a positive prick test for systemic atopies. Results: A total of 170 patients were evaluated, and 34 patients (68 eyes) were analyzed once the exclusion criteria were applied. The sample's mean age was 10.76 ± 2.31 years; with 19 (55.9%) men and 15 (44.1%) women. The mean keratometry in the flat meridian (Kflat), steep meridian (Ksteep), and maximum (Kmax) were 42.37 ± 1.63D, 43.53 ± 1.65D, and 43.90 ± 1.73D, respectively. The mean values for corneal asphericity (ε2) and thinnest point were 0.28 ± 0.11 and 550.20 ± 37.90 μm, respectively. The inferior-superior asymmetry ratio (I-S) and coma were 0.74 ±0.59D and 0.28 ± 0.12D, respectively. Conclusion: The knowledge of normal corneal tomographic parameters and their variation in children and adolescents without corneal disease or atopy may be useful for diagnosing keratoconus and initiating early disease treatment.


RESUMO Objetivo: Identificar parâmetros tomográficos de normalidade em córneas de crianças e adolescentes sem a presença de atopias sistêmicas e alergias oculares. Métodos: Este estudo descritivo transversal avaliou pacientes com idade entre 8 e 16 anos que foram submetidos a exame biomicroscópico completo por lâmpada de fenda e avaliação tomográfica da córnea por tomógrafo dual Scheimpflug, excluindo pacientes com doença ocular (incluindo conjuntivite alérgica) ou prick test positivo para atopias sistêmicas. Resultados: Cento e setenta pacientes foram avaliados e após cumpridos os critérios de exclusão, 34 (68 olhos) foram analisados. A média etária da amostra foi 10,76 ± 2,31 anos; 19 (55,9%) eram meninos e 15 (44,1%) meninas. A média da ceratometria em dioptrias (D) no meridiano mais plano (Kflat), mais curvo (Ksteep) e máxima (Kmax) foram 42,37 ± 1,63D, 43,53 ± 1,65D e 43,90 ± 1,73D, respectivamente. Os valores médios da asfericidade corneana (ε2) e do ponto mais fino da córnea foram 0,28 ± 0,11 e 550,20 ± 37,90 micras (μm). A assimetria corneana inferior-superior (I-S) e coma foi em média 0,74 ± 0,59D e 0,28 ± 0,12D, respectivamente. Conclusão: O conhecimento dos valores médios e sua variação de parâmetros tomográficos da córnea em crianças e adolescentes sem atopias sistêmicas ou alergias oculares pode ser útil para o diagnóstico precoce do ceratocone e o seu tratamento em estágio inicial.

2.
Arq. bras. oftalmol ; 87(1): e2021, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527817

ABSTRACT

ABSTRACT Keratoconus is a progressive disorder that manifests as a cone-like steepening of the central or paracentral inferior cornea and irregular stromal thinning. There is a gradual decrease in visual acuity due to corneal asymmetry, irregular astigmatism, and increased optical aberrations, consequently impacting the quality of life. Several procedures have been developed in an attempt to slow or reverse the progression. The Bader procedure, which includes a pattern of incisions around the circumference of the cornea and at the base of the protruding cone, is one such surgery. These incisions penetrate 70-90% of the cornea's depth. Its goal is to flatten the topography and reduce corneal asymmetry and irregular astigmatism. Though prior research found these to be highly promising, we report a patient who was given contact lenses to restore and maintain his vision while his corneal ectasia and thinning progressed over the following decade.


RESUMO O ceratocone é uma doença progressiva que se manifesta como uma elevação semelhante a um cone da cór­nea central ou paracentral inferior e é associada a uma re­dução irregular da espessura do estroma. Há uma diminuição gradual da acuidade visual devido à assimetria da córnea, ao astigmatismo irregular e a um aumento das aberrações ópticas, o que prejudica a qualidade de vida. Foram desenvolvidos vários procedimentos para tentar interromper ou mesmo reverter a evolução da doença. Um deles é o chamado procedimento de Bader, que inclui um padrão de incisões em volta da circunferência da córnea e na base do cone protuberante. Essas incisões penetram até 70%-90% da profundidade da córnea e têm o objetivo de achatar a topografia e diminuir a assimetria da córnea e o astigmatismo irregular. Embora essa técnica seja muito promissora, segundo um estudo anterior, aqui se apresenta o caso de um paciente no qual esses objetivos não foram atingidos. Esse paciente recebeu lentes de contato para restaurar e manter sua visão, enquanto sua ectasia corneana e a redução da espessura progrediram ao longo da década seguinte.

3.
International Eye Science ; (12): 301-306, 2024.
Article in Chinese | WPRIM | ID: wpr-1005399

ABSTRACT

AIM: To evaluate the clinical outcomes of using the cross-positioning method for correcting low and moderate astigmatism during small incision lenticule extraction(SMILE)surgery with Alpins vector analysis.METHODS: A total of 50 patients(81 eyes)with low and moderate astigmatism with the rule ≤1.50 D who underwent SMILE surgery at the laser myopia treatment center of Xi'an No.1 Hospital from May 2022 to November 2022 were included in the prospective randomized controlled study, and they were divided into two groups according to the random table, with 25 case(41 eyes)in cross-positioning group and 25 cases(40 eyes)in control group. In the cross-positioning group, the patients' head position was adjusted based on the cross intersection lines before the standard SMILE procedure, aligning the lateral canthi with the horizontal line and the midpoint of the eyebrows and the nose bridge with the vertical line. Postoperative visual acuity and refractive results at 3 mo were observed in both groups, and astigmatic changes were analyzed and evaluated using the Alpins vector analysis method.RESULTS: During the follow-up period, 6 cases(11 eyes)in the cross-positioning group were lost to follow-up, while in the control group, 8 cases(14 eyes)were lost to follow-up, with 19 cases(30 eyes)and 17 cases(26 eyes)finally included in the cross-positioning group and the control group, respectively. At 3 mo postoperatively, the uncorrected visual acuity(UCVA)of both groups' operated eyes was ≥1.0, and no serious complications occurred, with no significant differences in UCVA, best corrected visual acuity(BCVA), spherical power, and spherical equivalent between the cross-positioning group and the control group(all P>0.05). The cylindrical power in the cross-positioning group was 0.00(0.00, 0.00)D, which was lower than -0.13(-0.50, 0.00)D in the control group(P=0.01). The vector analysis results showed that the difference vector(DV)in the cross-positioning group was lower than that in the control group [0.00(0.00, 0.00)vs 0.13(0.00, 0.50), P=0.01], and the index of success(IOS)was better than that of the control group [0.00(0.00, 0.00)vs 0.18(0.00, 0.77), P<0.01]. At 3 mo postoperatively, 26(87%)and 15(58%)eyes in the cross-positioning group and control groups achieved an angle of error(AE)within ±5°, respectively.CONCLUSION: The cross positioning method was used to calibrate the patients' head position during SMILE surgery, which reduced the axial position error and improved the accuracy of SMILE in correcting low and moderate astigmatism.

4.
International Eye Science ; (12): 162-165, 2024.
Article in Chinese | WPRIM | ID: wpr-1003528

ABSTRACT

AIM: To explore the characteristics of astigmatism distribution among preschool children from Tongzhou District, Beijing, discuss its categorizations, severity, and the effect on preschoolers' vision, and clarify the influence of cycloplegic refraction on the detection of astigmatism.METHODS:In this cross-sectional study conducted from December 2021 to January 2022, a cluster random sampling method was utilized to assess 1 498 preschool children(2 996 eyes)from Tongzhou District, Beijing. The sample comprised 791 males and 707 females, with 222 children aged 3 to <4 years, 521 children aged 4 to <5 years, 647 children aged 5 to <6 years, and 108 children aged 6 to <7 years. Evaluations included visual acuity, anterior segment, computerized optometry, and cycloplegic refraction.RESULTS:Prior to cycloplegic refraction, the prevalence of astigmatism was found to be 61.88%(927/1498). For post-cycloplegic refraction, this percentage slightly increased to 64.02%(959/1498, P=0.095). Following cycloplegic refraction, the distribution of astigmatism severity was as follows: 51.87%(777/1498)had mild astigmatism, 9.41%(141/1498)had moderate astigmatism, and 2.74%(41/1498)had severe astigmatism. Astigmatism was predominantly with-the-rule across all age groups, with compound hyperopic astigmatism being the most frequent type. In cases of subnormal vision caused by astigmatism: low degree accounted for 9.38%, moderate degree accounted for 25.4%,and high degree accounted for 52.6%.CONCLUSION:The findings reveal a high incidence of astigmatism in preschool children, predominantly in a mild nature. Cycloplegic refraction was observed to have a negligible effect on the rate of astigmatism detection. Moreover, its impact on vision becomes more significant as the degree of astigmatism increases.

5.
Braz. J. Psychiatry (São Paulo, 1999, Impr.) ; 45(5): 397-404, Sept.-Oct. 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1527996

ABSTRACT

Objectives: The present study analyzed the reciprocal relationships between four common pediatric ophthalmic diseases (i.e., hyperopia, myopia, astigmatism, and strabismus) and attention‐deficit/hyperactivity disorder (ADHD) in children. Methods: This study enrolled 86,028 children with ADHD and 1,798,673 children without ADHD in the Taiwan Maternal and Child Health Database who were born at any time from 2004 to 2017. Cox proportional hazards regression models were used to estimate the bidirectional relationships of the four ophthalmic diseases with ADHD in children after adjusting for age, sex, and gestational age at birth. Survival curves for time-to-event variables were estimated using the Kaplan-Meier method, and the log-rank test was used to compare the curves. Results: The results indicated that ADHD significantly predicted the occurrence of hyperopia, myopia, astigmatism, and strabismus. Furthermore, hyperopia, myopia, astigmatism, and strabismus significantly predicted the occurrence of ADHD. The time between enrollment and ADHD diagnosis was shorter for patients with ophthalmic diseases than for the control group, and the time between enrollment and ophthalmic disease diagnosis was also shorter for ADHD patients than for the control group. Sex differences were found in the associations between ADHD and ophthalmic diseases. Conclusion: Clinicians should monitor children with ADHD for hyperopia, myopia, astigmatism, and strabismus to ensure appropriate treatment, and vice versa.

6.
Indian J Ophthalmol ; 2023 Sep; 71(9): 3242-3245
Article | IMSEAR | ID: sea-225249

ABSTRACT

The comorbidity of keratoconus with Fuchs� endothelial dystrophy with cataract is a rare clinical combination. We present an amalgamation of surgical techniques to manage the above clinical conditions and its complications in single setting. The modified triple procedure, namely, the phacoemulsification, pinhole pupilloplasty, and pre-Descemet抯 endothelial keratoplasty (PDEK) in the order of description is followed in single sitting. Lens removal by phacoemulsification, correction of irregular astigmatism by pinhole pupilloplasty (pinhole optics), and exchanging the endothelial layer for PDEK forms the main segments of the triple procedure. This combination of techniques may decrease the risk of multiple surgeries and its related complications. Moreover, it will allow the patient for faster visual rehabilitation by improving the uncorrected visual acuity and visual quality.

7.
Indian J Ophthalmol ; 2023 Aug; 71(8): 2972-2977
Article | IMSEAR | ID: sea-225223

ABSTRACT

Purpose: To compare the visual outcomes and residual astigmatism following implantation of Eyecryl toric versus Alcon AcrySof IQ toric intra?ocular lenses (IOLs). Methods: This retrospective, observational study included 143 eyes of 141 patients who underwent phaco?emulsification, followed by implantation of Eyecryl toric IOL (n = 83 eyes) or Alcon toric IOL (n = 60 eyes) in an eye hospital in South India from 2018 to 2021. At 1 month post?op, the uncorrected distance visual acuity (UCVA), best corrected distance visual acuity (BCVA), and residual astigmatism of the toric IOL were compared and analyzed. Results: The mean pre?op corneal astigmatism was 2.02 ± 0.81 D and 1.70 ± 0.68 D in the Alcon and Eyecryl groups, respectively (P = 0.005). The mean post?op corneal astigmatism at 1 month was 0.50 ± 0.51 D and 0.36 ± 0.42 D in the Alcon and Eyecryl groups, respectively, with no statistically significant difference between them (P = 0.87). The mean post?op UCVA in logarithm of minimum angle of resolution (logMAR) at 1 month was similar between the groups at 0.17 ± 0.18 and 0.17 ± 0.16 in the Alcon and Eyecryl groups, respectively (P = 0.98). The mean post?op BCVA in logMAR at 1 month was 0.06 ± 0.09 and 0.03 ± 0.10 in the Alcon and Eyecryl groups, respectively (P = 0.02). Conclusion: Both Eyecryl toric and Alcon AcrySof IQ toric IOLs showed comparable post?operative outcomes in terms of UCVA and residual astigmatism. The post?op BCVA was clinically similar between groups but statistically better in the Eyecryl toric group

8.
Indian J Ophthalmol ; 2023 Aug; 71(8): 2967-2971
Article | IMSEAR | ID: sea-225212

ABSTRACT

Purpose: To evaluate whether the toric intra?ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over?correction or under?correction after operation. Methods: The present study included a mono?centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with?the?rule” (WTR) or “against?the?rule” (ATR) on the basis of the steep anterior corneal meridian. The post?operative refractive astigmatic prediction error was analyzed 1 month post?operatively using the vector analysis by the Alpins method and double?angle plots method. Results: The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over?correction. The mean over?correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48% <0.50D prediction error in the main analysis. Conclusions: The results suggested that in cases of high PCA, the toric IOL calculation, which was performed using TCA, may cause a potential over?correction in the ATR and WTR eyes. For ATR eyes, over?correction led to slight disruption of post?operative visual quality because of the “with?the?rule” residual astigmatism after operation. Therefore, we suggested using TCA for toric IOL calculation in ATR eyes.

9.
Indian J Ophthalmol ; 2023 Jun; 71(6): 2480-2486
Article | IMSEAR | ID: sea-225084

ABSTRACT

Purpose: To evaluate the clinical outcomes of preloaded toric intraocular lens (IOLs) implantation in eyes undergoing phacoemulsification. Methods: This prospective study included 51 eyes of 51 patients with visually significant cataracts and corneal astigmatism ranging between 0.75 and 5.50 D. All patients underwent phacoemulsification with SupraPhob toric intraocular lens implantation under topical anesthesia. The main outcome measures were uncorrected distance visual acuity (UDVA), residual refractive cylinder, spherical equivalent, and IOL stability at 3 months follow?up. Results: At 3 months, 49% (25/51) of patients had UDVA equal to or better than 20/25 with 100% of eyes achieving better than 20/40. Mean logMAR UDVA improved from 1.02 ± 0.39, preoperatively to 0.11 ± 0.10 at 3 months follow?up (P < 0.001, Wilcoxon signed?rank test). The mean refractive cylinder improved from ? 1.56 ± 1.25 D preoperatively to ? 0.12 ± 0.31 D at 3 months follow?up (P < 0.001) while the mean spherical equivalent value changed from ? 1.93 ± 3.71D preoperatively to ? 0.16 ± 0.27D (P = 0.0013). The mean root mean square value for higher order aberrations was 0.30 ± 0.18 ?m while the average contrast sensitivity value (Pelli?Robson chart) was 1.56 ± 0.10 log unit, at the final follow?up. The mean IOL rotation at 3 weeks was 1.7 ± 1.61 degrees, which did not change significantly at 3 months (P = 0.988) follow?up. There were no intraoperative or postoperative complications. Conclusion: SupraPhob toric IOL implantation is an effective method for addressing preexisting corneal astigmatism in eyes undergoing phacoemulsification with good rotational stability

10.
Indian J Ophthalmol ; 2023 Jun; 71(6): 2469-2473
Article | IMSEAR | ID: sea-225082

ABSTRACT

Purpose: To compare the visual outcomes in patients undergoing small?incision lenticule extraction (SMILE) for correction of myopic astigmatism (??1.50 D) with or without manual cyclotorsion compensation. Methods: A prospective, double?blinded, randomized, contralateral study was conducted in the refractive services of a tertiary eye care center. Eligible patients with bilateral high myopic astigmatism (?1.5 D) and intraoperative cyclotorsion (?5°) undergoing SMILE between June 2018 and May 2019 were included. Cyclotorsion compensation was performed using triple centration method before femtosecond laser delivery. Uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively) measurement, manifest refraction, slit?lamp biomicroscopy, and corneal tomography were performed preoperatively and at 1 and 3 months’ postoperative visit. Astigmatic outcomes were analyzed using Alpins criteria. Results: A total of 30 patients (60 eyes) were included in this study. The patients underwent bilateral SMILE surgery, with manual cyclotorsion compensation in one eye (CC group, n = 30 eyes) and no cyclotorsion compensation in the other eye (NCC group, n = 30 eyes). Preoperative astigmatism and intraoperative cyclotorsion were ?2.0 D and 7.03° ± 1.06° (CC) and ?1.75 D and 7.24° ± 0.98° (NCC) (P = 0.472 and 0.240, respectively). No significant differences were noted in mean refractive spherical equivalent (MRSE), UDVA, CDVA, and refractive error between the two groups at 3 months’ postoperative visit. Astigmatic outcomes measured using Alpins criteria demonstrated no significant difference between the two cohorts. Conclusion: The cyclotorsion compensation technique provided no additional advantage in terms of astigmatic outcomes or postoperative visual quality, in eyes with high preoperative astigmatism and intraoperative cyclotorsion.

11.
Indian J Ophthalmol ; 2023 May; 71(5): 2247-2250
Article | IMSEAR | ID: sea-225061

ABSTRACT

We report the outcomes of a custom-designed toric piggyback intraocular lens in a patient with high postoperative residual astigmatism. A 60-year-old male patient underwent customized toric piggyback IOL for postoperative residual astigmatism of 13 D, with follow-up examinations for IOL stability and refractive outcomes. The refractive error stabilized at two months and remained stable at one year, with a correction of nearly 9 D of astigmatism. The IOP remained within normal limits, and there were no postoperative complications. The IOL remained stable in the horizontal position. To our knowledge, this is the first case report of correction of unusually high astigmatism by a novel smart toric design of piggyback IOL.

12.
Article | IMSEAR | ID: sea-218455

ABSTRACT

Background: Uncorrected refractive error is one of the leading causes of visual impairment and blindness world-over. The distribution and pattern of presentation is variable depending on various factors. Regardless of the type, refractive errors are easily correctable with spectacles if diagnosed early.Objective: The objective of this study was to evaluate the pattern of refractive errors among medical students at University of Zambia - School of Medicine.Methodology: This was a cross-sectional study conducted at the University Teaching Hospitals-Eye Hospital involving Master of Medicine, Master of Surgery (MBChB) students from third to seventh year of study at University of Zambia - School of Medicine, Ridgeway campus between October 2021 and March 2022. A total of 210 participants were recruited in the study. Subjects had non-cycloplegic autorefraction combined with a researcher administered questionnaire. Spherical equivalents (SE) ? - 0.50D were determined as myopia; SE of ? + 0.50D hyperopia and ? -0.50D cylinder as astigmatism. Statistical analysis was carried out using Stata version 13.0.Results: One hundred and forty-one (67.1%) subjects had a form of refractive error; 56.0%, 31.2% and 12.8% of them were astigmats, myopes or hyperopes, respectively. The prevalence of ametropia was 65.0 % in females and 69.0 % in males. Minus spherical errors ranged from -0.25 to -5.00D and plus spherical errors ranged from +0.25 to +3.00D. The mean spherical equivalent for the group was -0.45D. Parental history of refractive error was significantly associated with diagnosis of refractive error (p=0.001) while age and gender were not (p = 0.428 and 0.530, respectively). The majority (68.6%) of participants were not aware of their refractive error.Conclusion: The prevalence of refractive errors among medical students was high, with astigmatism being the most common type. The majority of those found with refractive error were not aware of the diagnosis.

13.
Indian J Ophthalmol ; 2023 Mar; 71(3): 946-950
Article | IMSEAR | ID: sea-224903

ABSTRACT

Purpose: India has the largest population of youth in the world, thereby making them important contributors to the “India of Tomorrow”. Over 80% of knowledge gained is by the visual sense, thereby making school screening programs a necessity in our country. Data from the pre?COVID era, that is, 2017–18 was collected from close to 19,000 children in Gurugram, Haryana, a tier two city in National Capital Region, India. A similar prospective observational study is planned post COVID?19 (2022–23) for further analysis to depict the impact of COVID?19 in these areas. Methods: The program They See, They Learn was set at government schools in the area of operations (district of Gurgaon, Haryana), where the children and their families were unable to afford eye care services. All children who were screened underwent a comprehensive eye examination at the school premises itself. Results: A total of 18,939 students were screened over a period of 18 months, covering a total of 39 schools in the Gurugram belt, in the first phase of the program. Eleven point eight percent (n = 2254) of all school students had some form of refractive error. Girl students were found to have a higher refractive error rate (13.3%) compared to boy students (10.1%) across the schools screened. Myopia was the most common type of refractive error. Conclusion: School students require perfect vision or else they can be discouraged and may become a major burden to the economy of any developing nation. A school screening program aiming at populations that cannot afford such basic needs like spectacles is a must in all zones of the country

14.
Indian J Ophthalmol ; 2023 Mar; 71(3): 751-756
Article | IMSEAR | ID: sea-224900

ABSTRACT

Purpose: To estimate the postoperative astigmatism after small?incision cataract surgery (SICS) done by junior residents at the end of 1 and 3 months. Methods: This observational longitudinal study was conducted at the Department of Ophthalmology of a tertiary eye care hospital and research center. 50 patients enrolled in the study underwent manual small incision cataract surgery by junior residents. Preoperative detailed ocular examination was done, which included keratometric estimation using autokeratometer (GR?3300K). Incision length, distance of incision from the limbus, and type of suturing technique were noted. Postoperatively, keratometric readings were noted at 1 and 3 months. Astigmatism (surgically induced astigmatism [SIA]) was estimated using Hill’s SIA calculator version 2.0. All the analyses were performed using Statistical Package for the Social Sciences (SPSS) ver. 26.0 (IBM Corp., USA) software, and the statistical significance was tested at a 5% level. Results: Out of 50 patients, 54% had SIA between 1.5 and 2.5 D and 32% had SIA of more than 2.5 D. Only 14% had SIA less than 1.5 D at the end of 1 month. While 52% had SIA between 1.5 and 2.5 D, 22% had SIA between 1.5 and 2.5 D and 26% had SIA less than 1.5 D at the end of 3 months. Conclusion: The SIA in most of the SICS done by junior residents was above 1.5 D. It depended mainly on the incision length, its distance from the limbus, and the suturing technique.

15.
Indian J Ophthalmol ; 2023 Feb; 71(2): 541-546
Article | IMSEAR | ID: sea-224842

ABSTRACT

Purpose: To evaluate a method using measured values of total corneal refractive power (TCRP) for a manufacturer’s online calculator by comparing it with the Barrett toric calculator (BTC) and Kane toric calculator (KTC) combined with simulated keratometry values (SimK). Methods: This was a retrospective case series. Patient records were reviewed to identify the patients who had biometry with the IOL Master 700 and Pentacam recorded before toric IOL implantation and refractive follow?up data after implantation. The predicted error in residual astigmatism was calculated by vector analysis according to the calculation methods and the measurements used. Results: A total of 70 eyes of 56 patients were included. The mean absolute astigmatism prediction errors were 0.6 ± 0.32, 0.59 ± 0.35, and 0.61 ± 0.35 D for the ATCTCRP, BTCSimK, and KTCSimK calculators, respectively (P = 0.934), and the centroid of the prediction errors were 0.3 D @ 178°, 0.11 D @ 102°, and 0.09 D @ 147°, respectively (P = 0.23). In the with?the?rule subgroup, the centroid of the prediction error was 0.34 D @ 176° for ATCTCRP and was the highest among the three calculation methods (P = 0.046). Conclusion: The ATCTCRP, BTCSimK, and KTCSimK calculators had similar performance with regards to their astigmatism prediction accuracy. The ATCTCRP calculator combined with 4.0?mm apex/ ring readings of TCRP was slightly intended to result in against?the?rule residual astigmatism.

16.
Indian J Ophthalmol ; 2023 Feb; 71(2): 467-475
Article | IMSEAR | ID: sea-224830

ABSTRACT

Purpose: To develop a nomogram in cases with mismatch between subjective and Topolyzer cylinder, and based on the magnitude of the mismatch, customize a treatment plan to attain good visual outcomes post?laser?assisted in situ keratomileusis (LASIK) surgery. Methods: The patients were evaluated preoperatively using corneal tomography with Pentacam. Five optimal corneal topography scans were obtained from the Topolyzer Vario were used for planning the LASIK treatment. For the nomogram purpose, the patients were divided into three categories based on the difference between the subjective cylinder and Topolyzer (corneal) cylinder. The first group (group 1) consisted of eyes of patients, where the difference was less than or equal to 0.4 D. The second group (group 2) consisted of eyes, where the difference was more than 0.4 D and the subjective cylinder was lesser than the Topolyzer cylinder. The third group (group 3) included eyes where the difference was more than 0.4 D but the subjective cylinder was greater than the Topolyzer cylinder. LASIK was performed with the WaveLight FS 200 femtosecond laser and WaveLight EX500 excimer laser. Assessment of astigmatism correction for the three groups was done using Aplins vector analysis. For comparison of proportions, Chi?square test was used. A P value less than 0.05 was considered statistically significant. Results: The UDVA was statistically significantly different when compared between groups 1 and 2 (P = 0.02). However, the corrected distance visual acuity (CDVA) was similar among all the three groups (P = 0.1). Group 3 showed an increase of residual cylinder by ?0.25 D, which was significant at intermediate and near reading distances (P < 0.05). Group 3 showed significantly higher target?induced astigmatism (TIA) compared to groups 1 and 2 (P = 0.01). The mean surgically induced astigmatism (SIA) was the least in group 2, which was statistically significant (P < 0.01). Conclusion: The outcomes for distance vision using our nomogram postoperatively were excellent, but further refinement for improving the near vision outcomes is required

17.
Arq. bras. oftalmol ; 86(5): e20230070, 2023. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1513677

ABSTRACT

ABSTRACT Purpose: Postoperative refraction in modern mi­croincision cataract surgery gained extra importance in patients with the previous laser-assisted in situ keratomileusis (LASIK) surgery. The surgically induced astigmatic changes in those eyes may differ not only in magnitude but also in direction compared to virgin corneas. This study aimed to compare the surgically induced astigmatic changes after microscopic cataract surgery between post-LASIK corneas and virgin eyes. Methods: Cases that underwent microincision cataract surgery in eyes with and without previous LASIK surgery were reviewed. The demographics, the axial length at cataract surgery, the central corneal thickness, spheric and cylindric values, keratometry readings, and postoperative posterior corneal astigmatism were retrospectively evaluated. A modified Alpins method was used for astigmatic vector analysis, and baseline astigmatism, surgically induced astigmatism, difference vector, flattening effect, and torque were assessed. Results: A total of 42 eyes from 24 subjects was evaluated. Group I consisted of 14 eyes with the previous LASIK, and Group II included 28 eyes without any refractive surgery. Preoperative mean central corneal thickness in Group I was significantly thinner (p=0.012). There was no significant difference in baseline astigmatism between the groups regarding magnitude and power vectors. After microincision cataract surgery, there were no significant differences in mean spheric and cylindric values and mean keratometry readings (all p>0.05). However, surgically induced astigmatism and difference vector were significantly higher on J45 vector component in post-LASIK eyes and microincision cataract surgery steepening effect on post-LASIK corneas was significantly higher than those in virgin eyes (p=0.001, p=0.002 and p=0.018, respectively). Conclusions: Cataract surgery has steepened the corneas in both groups with a significantly higher steepening effect in post-LASIK eyes. Certainly, corneal topography cataract surgery is particularly helpful to provide more precise surgically induced astigmatism interpretations.


RESUMO Objetivo: A refração pós-operatória na cirurgia mo­derna de catarata por microincisão ganha ainda mais importância em pacientes com cirurgia prévia de ceratomileuse in situ assistida por laser (LASIK). As alterações astigmáticas induzidas cirurgicamente nesses olhos podem diferir não apenas em magnitude, mas também em direção em comparação com córneas virgens. O objetivo deste estudo foi comparar as alterações astigmáticas induzidas cirurgicamente após cirurgia de catarata por microincisão entre córneas pós-LASIK e olhos virgens. Métodos: Foi revisada uma série de casos de cirurgia de catarata por microincisão em olhos com e sem cirurgia LASIK anterior. Os dados demográficos, o comprimento axial no momento da cirurgia de catarata, a espessura central da córnea, os valores esféricos e cilíndricos, as leituras da ceratometria e o astigmatismo corneano posterior pós-operatório foram avaliados retrospectivamente. O método Alpins modificado foi usado para análise vetorial astigmática e foram avaliados o astigmatismo basal, o astigmatismo induzido cirurgicamente, o vetor de diferença, o efeito de achatamento e o torque. Resultados: Ao todo, 42 olhos de 24 indivíduos foram avaliados. O Grupo I consistiu em 14 olhos com LASIK prévio; o Grupo II incluiu 28 olhos sem qualquer cirurgia refrativa. A média da espessura corneana central pré-operatória no Grupo I foi significativamente mais fina (p=0,012). Não houve diferença significativa no astigmatismo basal entre os grupos em termos de magnitude e vetores de potência. Após a cirurgia de catarata por microincisão, não houve diferenças significativas nos valores médios esféricos, cilíndricos e leituras médias de ceratometria (todos com p>0,05). No entanto, o astigmatismo induzido cirurgicamente e o vetor de diferença foram significativamente maiores no componente do vetor J45 em olhos pós-LASIK, e o efeito de aumento da inclinação pela cirurgia de catarata por microincisão nas córneas pós-LASIK foi significativo em comparação com olhos virgens (p=0,001, p=0,002 e p=0,018, respectivamente). Conclusões: A cirurgia de catarata aumentou a inclinação das córneas em ambos os grupos, sendo esse aumento significativamente maior nos olhos pós-LASIK. Certamente, a topografia da córnea antes da cirurgia de catarata é particularmente útil para fornecer interpretações mais precisas do astigmatismo induzido cirurgicamente.

18.
Rev. bras. oftalmol ; 82: e0016, 2023. graf
Article in Portuguese | LILACS | ID: biblio-1431669

ABSTRACT

RESUMO Objetivo: Analisar retrospectivamente as alterações na ceratometria e no astigmatismo corneano obtidas após cirurgia de implante de anel intraestromal, comparando o uso de um segmento de arco longo versus o implante de dois segmentos de comprimento de arco tradicional. Métodos: A partir de um estudo transversal, obtivemos os dados de 94 olhos de pacientes diagnosticados com ceratocone, que foram submetidos ao implante de anel corneano. Eles foram divididos em dois grupos, dependendo do tipo de implante recebido: Grupo A, um segmento de arco longo; Grupo B, dois segmentos tradicionais. Todos os segmentos implantados possuíam 250µ de espessura. Os dados do pré-operatório dos dois grupos foram comparados, para garantir que as amostras eram similares (as diferenças encontradas entre os dois grupos não eram estatisticamente significativas). As variáveis analisadas no pré e no pós-operatório foram acuidade visual com correção, ceratometria, astigmatismo corneano e refração. Resultados: A amostra que recebeu apenas um segmento de arco longo (Grupo A) obteve redução da ceratometria média de 4,42D (8,7%) e do astigmatismo corneano de 2,43D (40,4%). Já na amostra dos olhos que receberam dois segmentos de arco tradicional (Grupo B), houve redução média de 2,66D (5,1%) em relação à ceratometria média e redução média de 2,11D (34,8%) em relação ao astigmatismo corneano. A redução obtida na ceratometria média no Grupo A foi maior que a obtida no Grupo B (diferença estatisticamente significativa). A redução obtida no astigmatismo do Grupo A não foi estatisticamente significante, se comparada com o resultado obtido no Grupo B (considerando p≤0,05). Conclusão: Foi demonstrado que o uso de um segmento de arco longo possui maior capacidade de aplanação corneana, se comparado com o uso de dois segmentos com comprimento de arco tradicional. Em relação à redução do astigmatismo, os dois grupos mostraram resultados equivalentes.


ABSTRACT Purpose: To retrospectively analyze the changes in corneal keratometry and astigmatism after intrastromal ring surgery, comparing the use of one long arch segment versus two traditional arc length segments. Methods: A cross-sectional study obtained data from 94 eyes of patients diagnosed with keratoconus that underwent surgical treatment with corneal ring implant. They were divided into two groups according to the type of implant received: one long-arch segment (Group A) or two traditional segments (Group B), both 250 microns thick. Preoperative data from the two groups were compared to ensure that the samples were similar (the differences between the two groups were not statistically significant). The variables (pre and post-operatively) analyzed were: best corrected visual acuity, keratometry, corneal astigmatism and refraction. Results: Group A, which received one long arch segment, showed a Km decrease of 4.42D (8.7%) and a corneal astigmatism reduction of 2.43D (40.4%). Group B, where the eyes acquired two traditional arch segments, showed an average Km decrease of 2.66D (5.1%) and corneal astigmatism reduction of 2.11D (34.8%). The mean keratometry (Km) reduction obtained was statistically significant (p≤0.05) when comparing both groups (A and B). The mean corneal astigmatism reduction was not statistically significant (p≤0.05) when comparing both groups (A and B). Conclusions: One long-arch segment has been demonstrated to have a greater capacity to reduce corneal curvature when compared to the use of two traditional-sized arch segments. No significant differences were found regarding the reduction of corneal astigmatism after comparing the results obtained in both groups.


Subject(s)
Humans , Male , Female , Child , Adolescent , Adult , Middle Aged , Prostheses and Implants , Corneal Stroma/surgery , Prosthesis Implantation/methods , Keratoconus/surgery , Refraction, Ocular , Astigmatism , Visual Acuity , Cross-Sectional Studies , Treatment Outcome , Corneal Topography , Corneal Pachymetry
19.
Journal of Xi'an Jiaotong University(Medical Sciences) ; (6): 263-270, 2023.
Article in Chinese | WPRIM | ID: wpr-1005754

ABSTRACT

【Objective】 To investigate the influencing factors of surgically induced astigmatism (SIA) in phacoemulsification. 【Methods】 Cataract phacoemulsification was performed in 69 patients with regular corneal astigmatism from December 2021 to March 2022. SIA of the anterior corneal surface, posterior corneal surface and simulated keratometry (SimK) in the diameter range of 3 mm, 5 mm and 7 mm centered at the apex of the cornea was observed. Pearson correlation analysis was used to analyze SIA with age, axial length (AL), anterior chamber depth (ACD), white-to-white (WTW), and central corneal thickness (CCT). Multiple linear regression was used to analyze the influencing factors of SIA. 【Results】 The mean age of the 69 patients was (63.25±14.74) years old, and 28 (40.58%) were male. The analysis found that the |SIA| of SimK was negatively correlated with WTW (r=-0.265, P=0.028), the |SIA| of 3 mm, 5 mm, 7 mm anterior surface was negatively correlated with WTW (r=-0.320, P=0.007; r=-0.337, P=0.005; r=-0.287, P=0.017), and the |SIA| of 3 mm, 5 mm, 7 mm posterior surface was negatively correlated with AL (r=-0.390, P=0.001; r=-0.352, P=0.003; r=-0.317, P=0.008). Multiple regression analysis showed that WTW was negatively correlated with |SIA| of SimK, 3 mm, 5 mm, 7 mm anterior surface and 3 mm posterior surface (B=-0.261, P=0.047; B=-0.387, P=0.016; B=-0.323, P=0.009; B=-0.297, P=0.041; B=-0.085, P=0.049). WTW was positively correlated with XSIA of 3 mm anterior surface, YSIA of 5 mm, and 7 mm anterior surface (B=0.347, P=0.040; B=0.318, P=0.034; B=0.403, P=0.010). AL was negatively correlated with |SIA| on the posterior surface of 3 mm and 5 mm (B=-0.023, P=0.021; B=-0.034, P=0.030). 【Conclusion】 During cataract surgery, the effect of ocular biological parameters such as axial length and corneal diameter on SIA should be considered.

20.
International Eye Science ; (12): 1466-1470, 2023.
Article in Chinese | WPRIM | ID: wpr-980534

ABSTRACT

AIM: To evaluate the effect of preoperative degrees of myopic astigmatism and anterior corneal curvature on the functional optical zone(FOZ)after transepithelial photorefractive keratectomy(TransPRK).METHODS: Retrospective study was conducted on 78 patients(130 eyes)with myopia and myopic astigmatism who underwent TransPRK, and they were divided into control group(cylinder 0D), moderate astigmatism group(-0.50~-2.00D)and high astigmatism group(&#x003E;-2.00~&#x003C;-6.00D). The FOZ was measured and compared among the three groups 6mo after operation. The correlations between attempted correction, anterior corneal curvature, corneal aberrations, Q value, and the FOZ were analyzed.RESULTS: At 6mo after operation, the mean FOZ was 5.16±0.12mm in the control group, 5.29±0.23mm in the moderate astigmatism group, and 5.49±0.23mm in the high astigmatism group(P&#x003C;0.001), and the FOZ of the high astigmatism group was significantly higher than moderate astigmatism and control group(P&#x003C;0.05, P&#x003C;0.001); Pearson correlation analysis showed that the changes in spherical equivalent, total corneal higher-order aberrations(HOAs), coma, and spherical aberration were all negatively correlated with FOZ(all P&#x003C;0.05); and FOZ positively correlated with changes in the steep curvature(K2), mean curvature(Km), corneal astigmatism, and Q value(all P&#x003C;0.01). Multiple linear regression analysis showed that there was still positive correlation between preoperative K2 and FOZ after adjusting for other risk factors(P&#x003C;0.001).CONCLUSION: Patients with high astigmatism can obtain a larger FOZ and less induced coma after TransPRK. A larger FOZ can be achieved in eyes with steeper keratometry.

SELECTION OF CITATIONS
SEARCH DETAIL